Fencing Performance Data Sheet
NO | item | Standard | Product scope | Result | Remarks | Application |
---|---|---|---|---|---|---|
1 | Reach | (EC) No 1907/2006 | All WPC | Pass | Test Harmful contents | Hazardous substance Testing |
2 | Pedestal Vertical load test | EN 12825 :2001 | Pedestal | Pedestal loading test | Mechanical Test |
|
3 | Fire Performance | EN 13501 | ALL WPC | Bf1 S1 | Fire proofing Test |
|
4 | Fire Performance | ASTM E 81 | All WPC | Class A Top Level | Fire proofing Test |
|
5 | Pendulum Test | EN 15531-1:2014 and CEN/TS 15676 : 2007 | Suprotect | pass | Slip Resistance | Safety Performance |
6 | Moisture Resistance Boiling Test | EN 15534:-1 :2014 | Suprotect | pass | Durability |
|
7 | Abrasion Resistance | ASTM D4060-14 | Suprotect | 37.9mg/1000r | Durability |
|
8 | Resistance to Artificial Weathering | EN15534-1:2014 | Suprotect | 4.5 Grade of colorfastness | 2000h | Durability |
9 | Wind Resistance Test | Fence | Pass-No failiure or disengagement | 9-Scale Wind Load | Safety Performance |
|
10 | Moisture Content | EN322.1993 | All WPC | 0.89% | Durability - Waterproof |
|
11 | Falling Mass Impact Resistance | EN15534-1:2014 | Normal WPC | 9mm | Residual Indentation | Mechanical Test |
12 | Bending Strength | EN15534-1:2014 | All WPC | 26.8MPa | Mechanical Test |
|
13 | Modulus of Elasticity | EN15534-1:2014 | All WPC | 3758MPa | Mechanical Test |
|
14 | Withdrawal Capacity of Fasteners | EN13446:2002 | All WPC | 4139N | Screw Surface Withdrawal Test | Mechanical Test |
15 | Withdrawal Capacity of Fasteners | EN13446:2002 | All WPC | 3370N | Screw Edge Withdrawal Test | Mechanical Test |
16 | Coefficient of Linear Thermal Expansion | ISO 11359-2:1999 | All WPC | 66.75μm/m·℃ | Material Performance |
|
17 | Deflection Temperature under Load | ISO 75:2013 & ISO 75-2:2013 | All WPC | 80℃ | Durability |
|
18 | Oxygen Index | ASTM D2863-13 | Normal WPC | 21.80% | Fire-Resistance | Fire-Proofing Test |
19 | Anti-Slip Property | DIN 51130-2014 | Suprotect | R10 | Safety Performance |
|
20 | Falling Mass Impact Resistance | EN15534-1:2014 | Suprotect | 0.16mm | Testing the Depth of Residual Indentation | Mechanical Test |
21 | Resistance to Indentation | EN15534-1:2014 | Suprotect | Brinell Hardness: 65N/mm2 Rate of Elestic Recovery:77.7% | Durability |
|
22 | Rockwell Hardness | ASTM D785-08 | Suprotect | 83.3R | Surface Hardness | Durability |
23 | Coefficient of Linear Thermal Expansion | EN15534-1:2014 | Hyper Wood | 38.6 | Material Performance |
|
24 | Bending Strength | EN15534-1:2014 | Hyper Wood | 46MPa | Mechanical Test |
|
25 | Modulus of Elasticity | EN15534-1:2014 | Hyper Wood | 4300MPa | Mechanical Test |
|
26 | Flexural Breaking Load | GB/T 24508-2009 | All WPC | 4091N | Pass | Mechanical Test |
27 | Falling Mass Impact Resistance | GB/T 24508-2009 | All WPC | 6-7mm | Pass | Mechanical Test |
28 | Density | GB/T 24508-2009 | All WPC | 1.22 | Pass | Material Performance |
29 | Water Absorption Rate | GB/T 24508-2009 | All WPC | 0.90% | Pass | Material Performance |
30 | Falling Ball Impact Test at Low Temperature | GB/T 24508-2009 | All WPC | -10℃ No Crack | Pass | Material Performance |
31 | Dimension Changing Ratio of Swelling after Immersion in Water | GB/T 24508-2009 | All WPC | <0.1 | Pass | Material Performance |
32 | Dimension Changing Ratio ager Heated | GB/T 24508-2009 | All WPC | 0.20% | Pass | Material Performance |
33 | Thermal-Cold Cycliing Resistance | GB/T 24508-2009 | All WPC | No Cracking, No Bubble,0.2 | Pass | Durability |
34 | Stain Resistance of Surface | GB/T 24508-2009 | All WPC | No Significant Change | Pass | Durability |
35 | Freez-Thaw Resistance | GB/T 24508-2009 | All WPC | 94% | Pass | Durability |
36 | Creep Recovery Ratio | GB/T 24508-2009 | All WPC | 83% | Pass | Mechanical Test |
37 | Slip Resistance | GB/T 24508-2009 | All WPC | 45 | Pass | Safety Performance |
38 | Formaldehyde Emission | GB/T 24508-2009 | All WPC | E0-lowest level | Pass | Safety Performance |
39 | Dissoluble Lead | GB/T 24508-2009 | All WPC | <0.5 | Pass | Safety Performance |
40 | Dissoluble Cadmium | GB/T 24508-2009 | All WPC | <0.5 | Pass | Safety Performance |